POWER FACTOR CORRECTION PDF

Friday, April 26, 2019


Question #5: How Long Will It Take My Investment in Power Factor. Correction to Pay for Itself? Question #6: What is the Next Step? Question #1: What is Power. LV AND HV CAPACITOR BANKS. Fixed or automatic for power factor correction. Different low or high voltage solutions according to the characteristics of your. POWER FACTOR is the ratio between the useful (true) power (kW) to the total ( apparent) power (kVA) consumed by an item of a.c. electrical equipment or a.


Author:TERRESA MANTER
Language:English, Spanish, Dutch
Country:Senegal
Genre:Business & Career
Pages:457
Published (Last):25.08.2016
ISBN:600-4-70003-839-7
ePub File Size:18.78 MB
PDF File Size:14.84 MB
Distribution:Free* [*Regsitration Required]
Downloads:38705
Uploaded by: RANDY

Effective August Supersedes November Capacitor banks and passive harmonic filters. Technical Data SAE. Power factor correction. PF correction provides many benefits: . Power Factor Correction – 15 kVAR. kVAR. Added . For more info: cittadelmonte.info~grady/POWERFAC. pdf. FRAKO power factor correction (PFC) systems make a major contribution to achieving . Before venturing into the details in the design of power factor correction.

Skip to main content. Log In Sign Up. Saran Chaladying. The most important device in power factor correction is a capacitor. A capacitor for power factor correction can be classified to three categories according to voltage level of power network. The voltage classification according to IEC std. I Size of capacitor In three-phase network, to supply the Fig.

I Size of capacitor In three-phase network, to supply the Fig. The part of various failure of electrical device has been caused by high voltage rise due to capacitor switching.

Voltage rise due to switching of each capacitor configuration can be determined in eq. Voltage rise due to switching of Fig. III Unbalance voltage In the instance of one cell of the star connection capacitor or one in three phase of the star connection is failed, there is potential or difference unbalance load on each phase of the star connection capacitor. This will effectively destroyed a capacitor due to unbalance voltage as shown in Fig.

However, the delta connection In the instance of one cell of the delta cannot be supported to apply in medium or connection capacitor or one in three phase high voltage power network because of the delta connection has been failed, the application of the delta connection circuit connection in the delta connection capacitor in network with high voltage capacitor will move from the closed delta level must be had the large size to support to the opened delta configuration.

Reactive high voltage drop on capacitor when power of capacitor is dropped but voltage connected capacitor in medium or high on each phase of capacitor stays the same. As shown in eq. Type of high voltage level. Configuration of capacitor capacitor configuration can be classified in for low voltage and medium voltage accordance with fundamental electrical capacitor shown in Fig. The delta connection capacitor has been extensively applied in low voltage power network because the delta connection capacitor has smaller size and friendlier to the electrical environment unbalance voltage and voltage rise due to switching than the star connection capacitor.

However, in medium or high voltage power network the delta connection cannot be applied to correct the power factor in power network. Thus the star connection Fig. German, Related Papers. There is also a difference between a lagging and leading power factor. The terms refer to whether the phase of the current is leading or lagging the phase of the voltage. When power factor is equal to 0, the energy flow is entirely reactive and stored energy in the load returns to the source on each cycle.

When the power factor is 1, all the energy supplied by the source is consumed by the load. Power factors are usually stated as "leading" or "lagging" to show the sign of the phase angle. Capacitive loads are leading current leads voltage , and inductive loads are lagging current lags voltage. If a purely resistive load is connected to a power supply, current and voltage will change polarity in step, the power factor will be 1, and the electrical energy flows in a single direction across the network in each cycle.

Inductive loads such as induction motors any type of wound coil consume reactive power with current waveform lagging the voltage. Capacitive loads such as capacitor banks or buried cable generate reactive power with current phase leading the voltage.

Both types of loads will absorb energy during part of the AC cycle, which is stored in the device's magnetic or electric field, only to return this energy back to the source during the rest of the cycle.

At low values of power factor, more apparent power needs to be transferred to get the same real power. This apparent power must be produced and transmitted to the load, and is subject to the losses in the production and transmission processes. Electrical loads consuming alternating current power consume both real power and reactive power.

The vector sum of real and reactive power is the apparent power. The presence of reactive power causes the real power to be less than the apparent power, and so, the electric load has a power factor of less than 1.

A high power factor is generally desirable in a power delivery system to reduce losses and improve voltage regulation at the load. Compensating elements near an electrical load will reduce the apparent power demand on the supply system. Power factor correction may be applied by an electric power transmission utility to improve the stability and efficiency of the network. Individual electrical customers who are charged by their utility for low power factor may install correction equipment to increase their power factor so as to reduce costs.

Power factor correction brings the power factor of an AC power circuit closer to 1 by supplying or absorbing reactive power, adding capacitors or inductors that act to cancel the inductive or capacitive effects of the load, respectively.

In the case of offsetting the inductive effect of motor loads, capacitors can be locally connected. These capacitors help to generate reactive power to meet the demand of the inductive loads. This will keep that reactive power from having to flow all the way from the utility generator to the load. In the electricity industry, inductors are said to consume reactive power and capacitors are said to supply it, even though reactive power is just energy moving back and forth on each AC cycle.

The reactive elements in power factor correction devices can create voltage fluctuations and harmonic noise when switched on or off. They will supply or sink reactive power regardless of whether there is a corresponding load operating nearby, increasing the system's no-load losses.

In the worst case, reactive elements can interact with the system and with each other to create resonant conditions, resulting in system instability and severe overvoltage fluctuations. As such, reactive elements cannot simply be applied without engineering analysis.

An automatic power factor correction unit consists of a number of capacitors that are switched by means of contactors. These contactors are controlled by a regulator that measures power factor in an electrical network. Depending on the load and power factor of the network, the power factor controller will switch the necessary blocks of capacitors in steps to make sure the power factor stays above a selected value.

Instead of using a set of switched capacitors , an unloaded synchronous motor can supply reactive power. The reactive power drawn by the synchronous motor is a function of its field excitation. This is referred to as a synchronous condenser. It is started and connected to the electrical network.

It operates at a leading power factor and puts vars onto the network as required to support a system's voltage or to maintain the system power factor at a specified level. The synchronous condenser's installation and operation are identical to large electric motors.

Its principal advantage is the ease with which the amount of correction can be adjusted; it behaves like a variable capacitor. Unlike capacitors, the amount of reactive power supplied is proportional to voltage, not the square of voltage; this improves voltage stability on large networks. Synchronous condensers are often used in connection with high-voltage direct-current transmission projects or in large industrial plants such as steel mills.

These systems are able to compensate sudden changes of power factor much more rapidly than contactor-switched capacitor banks, and being solid-state require less maintenance than synchronous condensers.

Examples of non-linear loads on a power system are rectifiers such as used in a power supply , and arc discharge devices such as fluorescent lamps , electric welding machines, or arc furnaces. Because current in these systems is interrupted by a switching action, the current contains frequency components that are multiples of the power system frequency. Distortion power factor is a measure of how much the harmonic distortion of a load current decreases the average power transferred to the load.

In linear circuits having only sinusoidal currents and voltages of one frequency, the power factor arises only from the difference in phase between the current and voltage. This is "displacement power factor". Non-linear loads change the shape of the current waveform from a sine wave to some other form. Non-linear loads create harmonic currents in addition to the original fundamental frequency AC current. This is of importance in practical power systems that contain non-linear loads such as rectifiers , some forms of electric lighting, electric arc furnaces , welding equipment, switched-mode power supplies , variable speed drives and other devices.

Filters consisting of linear capacitors and inductors can prevent harmonic currents from entering the supplying system. To measure the real power or reactive power, a wattmeter designed to work properly with non-sinusoidal currents must be used. The distortion power factor is the distortion component associated with the harmonic voltages and currents present in the system. This definition with respect to total harmonic distortion assumes that the voltage stays undistorted sinusoidal, without harmonics.

This simplification is often a good approximation for stiff voltage sources not being affected by changes in load downstream in the distribution network. The result when multiplied with the displacement power factor DPF is the overall, true power factor or just power factor PF:.

In practice, the local effects of distortion current on devices in a three-phase distribution network rely on the magnitude of certain order harmonics rather than the total harmonic distortion.

For example, the triplen, or zero-sequence, harmonics 3rd, 9th, 15th, etc.

In a delta-wye transformer , these harmonics can result in circulating currents in the delta windings and result in greater resistive heating.

In a wye-configuration of a transformer, triplen harmonics will not create these currents, but they will result in a non-zero current in the neutral wire.

This could overload the neutral wire in some cases and create error in kilowatt-hour metering systems and billing revenue.

Eddy current losses generally increase as the square of the frequency, lowering the transformer's efficiency, dissipating additional heat, and reducing its service life. Negative-sequence harmonics 5th, 11th, 17th, etc. In generators and motors, these currents produce magnetic fields which oppose the rotation of the shaft and sometimes result in damaging mechanical vibrations.

Historically, these very-low-cost power supplies incorporated a simple full-wave rectifier that conducted only when the mains instantaneous voltage exceeded the voltage on the input capacitors. This leads to very high ratios of peak-to-average input current, which also lead to a low distortion power factor and potentially serious phase and neutral loading concerns.

A typical switched-mode power supply first converts the AC mains to a DC bus by means of a bridge rectifier or a similar circuit. The output voltage is then derived from this DC bus. The problem with this is that the rectifier is a non-linear device, so the input current is highly non-linear.

That means that the input current has energy at harmonics of the frequency of the voltage. This presents a particular problem for the power companies, because they cannot compensate for the harmonic current by adding simple capacitors or inductors, as they could for the reactive power drawn by a linear load. Many jurisdictions are beginning to legally require power factor correction for all power supplies above a certain power level.

Regulatory agencies such as the EU have set harmonic limits as a method of improving power factor. Declining component cost has hastened implementation of two different methods.

Power factor

The filter consists of capacitors or inductors, and makes a non-linear device look more like a linear load. An example of passive PFC is a valley-fill circuit. A disadvantage of passive PFC is that it requires larger inductors or capacitors than an equivalent power active PFC circuit.

Active PFC is the use of power electronics to change the waveform of current drawn by a load to improve the power factor. Active power factor correction can be single-stage or multi-stage. In the case of a switched-mode power supply, a boost converter is inserted between the bridge rectifier and the main input capacitors. The boost converter attempts to maintain a constant DC bus voltage on its output while drawing a current that is always in phase with and at the same frequency as the line voltage.

Another switched-mode converter inside the power supply produces the desired output voltage from the DC bus. This approach requires additional semiconductor switches and control electronics, but permits cheaper and smaller passive components. It is frequently used in practice. For a three-phase SMPS, the Vienna rectifier configuration may be used to substantially improve the power factor.

That feature is particularly welcome in power supplies for laptops. Dynamic power factor correction DPFC , sometimes referred to as "real-time power factor correction," is used for electrical stabilization in cases of rapid load changes e.

Power factor - Wikipedia

DPFC is useful when standard power factor correction would cause over or under correction. Power factors below 1. This increases generation and transmission costs. For example, if the load power factor were as low as 0. Line current in the circuit would also be 1. Alternatively, all components of the system such as generators, conductors, transformers, and switchgear would be increased in size and cost to carry the extra current.